thumb_1222134037_32620

3 Ways single piot operated check valves,in line

d Specification 1/4" 3/8" 1/2" 3/4"
Pilot ratio 1:9.8 1:6.5 1:4.6 1:4.4
Max flow (L/min ) 15 30 45 80
Max pressure (Bar) 350 300 300 250
Cracking pressure (Bar) 2.5 5 3 0.5

USE AND OPERATION:
These valves are used to block the cylinder in one direction. The flow is free in one direction and blocked in the reverse direction until pilot pressure is applied.

APPLICATIONS:
Connect V to the pressure flow, C to the actuator's side you want the flow to be blocked and Pil to the pilot line.